Discover Anolytech’s range of disinfection systems designed to meet the unique needs of your industry. From compact models for smaller operations to high-capacity systems for large-scale industries, we offer flexible purchase and rental options to ensure bacteria-free water 24/7. Choose a solution tailored to your business and start benefiting from safe, efficient, and sustainable water disinfection.
Pressure-resistant reinforced hose with 6 mm inner diameter. Used to extend dosing installations where the pump is positioned...Read More
Pressure-resistant reinforced hose with 6 mm inner diameter. Used to extend dosing installations where the pump is positioned further from the injection point. Suitable for both cold and hot water applications. Sold by the meter.Injector for dosing in water pipes, intended for flow rates over 60 l/h. Used together with a dosing...Read More
Injector for dosing in water pipes, intended for flow rates over 60 l/h. Used together with a dosing pump to create additional dosing points in the system. Handles high flow rates and is used in larger facilities. Suitable for cold water – Max 45 °C.Signal and alarm light that clearly displays the current status of the system. Can be mounted close to...Read More
Signal and alarm light that clearly displays the current status of the system. Can be mounted close to machine or at a distance for better visibility. Provides quick indication in case of malfunctions or alarms.Complete softening package with water softener and separate salt extra capacity is needed – for example, multiple incoming...Read More
Complete softening package with water softener and separate salt extra capacity is needed – for example, multiple incoming water lines or high levels of lime (Ca) in the water. Improves water quality by reducing water hardness and protects the system from lime scale buildup.Signal cable for connection to dosing pumps, especially for the installation of additional dosing points. Ensures proper communication...Read More
Signal cable for connection to dosing pumps, especially for the installation of additional dosing points. Ensures proper communication between the pump and the control system.Ultrasonic flow meter for water pipes with dimensions DN25–400 (pipe 33–405 mm). Non-contact flow measurement through the pipe...Read More
Ultrasonic flow meter for water pipes with dimensions DN25–400 (pipe 33–405 mm). Non-contact flow measurement through the pipe wall. Can be used as an alternative to mechanical water meters. Not suitable for mixed materials.Mechanical water meter for measuring water flow in piping systems. Suitable for smaller pipe dimensions. Used in combination...Read More
Mechanical water meter for measuring water flow in piping systems. Suitable for smaller pipe dimensions. Used in combination with injector and bypass system. Connection is G25 and the meter handles temperatures up to 30 °C.Precise mechanical water meter for measuring flow in medium-sized pipe dimensions. Robust design, suitable for use in facilities...Read More
Precise mechanical water meter for measuring flow in medium-sized pipe dimensions. Robust design, suitable for use in facilities requiring continuous flow monitoring. Connection is DN25 (1") and the meter handles temperatures up to 45 °C.Particle filter for capturing very small particles down to 1 micron. Used as a pre-filter or control filter...Read More
Particle filter for capturing very small particles down to 1 micron. Used as a pre-filter or control filter in n systems. Extends the lifespan of equipment by reducing particle contamination. Especially suitable for older machines: V2, V2R and V3.Handheld digital instrument for measuring total chlorine in water (0–5 ppm). Provides accurate and rapid on-site measurements. Requires...Read More
Handheld digital instrument for measuring total chlorine in water (0–5 ppm). Provides accurate and rapid on-site measurements. Requires supplement with liquid reagents. Perfect for routine checks in water treatment facilities.Liquid reagent for use with Hanna’s measuring instrument for total chlorine. One package contains 300 doses. Essential for...Read More
Liquid reagent for use with Hanna’s measuring instrument for total chlorine. One package contains 300 doses. Essential for performing accurate chlorine measurements in water samples. For professional use in facilities working with water treatment.Laboratory test according to ISO 11731:2017 for accurate identification of Legionella in drinking water. sample is submitted in...Read More
Laboratory test according to ISO 11731:2017 for accurate identification of Legionella in drinking water. sample is submitted in the included packaging. Provides exact CFU values (colony-forming units). The test must be analyzed within 24 hours of sampling.Rapid test for Legionella (Ultra One), lateral flow type. Provides results within 25 minutes and is used on-site...Read More
Rapid test for Legionella (Ultra One), lateral flow type. Provides results within 25 minutes and is used on-site in high-risk environments such as showers, cooling towers, water tanks, and pools. Sensitivity: 100 CFU/liter. Shelf life: 18 months from manufacturing date.Mars 2PC – an effective descaling agent for cleaning the internal parts of the machine. Removes limescale and...Read More
Mars 2PC – an effective descaling agent for cleaning the internal parts of the machine. Removes limescale and extends the lifespan of the equipment. Sold only in cartons of 3 bottles. Suitable for Anolytech's systems and similar dosing equipment.Rapid test strips for free chlorine in water, measurement range 0–5 ppm. Provides a visual indication of chlorine...Read More
Rapid test strips for free chlorine in water, measurement range 0–5 ppm. Provides a visual indication of chlorine level within seconds. Ideal for daily checks in smaller facilities or as a complement to digital instruments.Coarser particle filter with the capacity to filter particles down to 10 Used as a pre-filter in high-flow...Read More
Coarser particle filter with the capacity to filter particles down to 10 Used as a pre-filter in high-flow systems (Big Blue format). Protects equipment from particles and sediment. Primarily suitable for older machines: V2, V2R and V3, but also for new machines equipped with optional pre-filters. Full box, 6 psc.Spare part: Membrane for the DDA17 dosing pump. Replaced when worn to ensure proper pump function and precision....Read More
Spare part: Membrane for the DDA17 dosing pump. Replaced when worn to ensure proper pump function and precision.Spare part: Membrane for the DDA60 dosing pump. Replaced when worn to ensure proper pump function and precision....Read More
Spare part: Membrane for the DDA60 dosing pump. Replaced when worn to ensure proper pump function and precision.Spare part: Membrane for the DDA120 dosing pump. Replaced when worn to ensure proper pump function and precision....Read More
Spare part: Membrane for the DDA120 dosing pump. Replaced when worn to ensure proper pump function and precision.Spare part: Membrane for the DDA375 dosing pump. Replaced when worn to ensure proper pump and precision....Read More
Spare part: Membrane for the DDA375 dosing pump. Replaced when worn to ensure proper pump and precision.Complete pre-filter package with wall bracket and built-in 20 micron filter. Easy to install and replace. Used the...Read More
Complete pre-filter package with wall bracket and built-in 20 micron filter. Easy to install and replace. Used the first step in the filtration chain to protect downstream equipment from dirt and particles.Foot valve installed at the bottom of the suction hose to prevent liquid from flowing back when the...Read More
Foot valve installed at the bottom of the suction hose to prevent liquid from flowing back when the is turned off. Equipped with a check valve and strainer to protect the pump from contaminants.For DDA60 and above. Foot valve installed at the bottom of the suction hose to prevent liquid from...Read More
For DDA60 and above. Foot valve installed at the bottom of the suction hose to prevent liquid from flowing back when the pump is turned off. Equipped with a check valve and strainer to protect the pump from contaminants.Ensure a hassle-free setup by reviewing our conditions for installation, covering water, power, and space requirements.
Access detailed safety information for AnoDes (Anolyt-pH) and MARS-2PC. These documents outline safe handling, storage, and usage guidelines to ensure compliance and safety in your operations. Download the relevant safety data sheet below to stay informed.
Ensure a hassle-free setup by reviewing our conditions for installation, covering water, power, and space requirements.
Access detailed safety information for AnoDes (Anolyt-pH) and MARS-2PC. These documents outline safe handling, storage, and usage guidelines to ensure compliance and safety in your operations. Download the relevant safety data sheet below to stay informed.
When Anolytech started in 2005, we envisioned creating a sustainable way to make water bacteria-free. Today, our site-produced disinfection system plays a vital role in helping businesses reduce the spread of infection, limit harmful chemicals, and conserve water resources. By switching to Anolytech’s environmentally friendly disinfection method, your business contributes directly to several of the UN’s 17 global goals, including health, environmental sustainability, and climate action.
Fill out the form, and one of our team members will get back to you as soon as possible. We’re happy to assist and would love to discuss how we can help with your disinfection needs—maybe even over a cup of coffee!